Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
J Biophotonics ; 17(4): e202300441, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38221644

RESUMO

Quantifying corneal elasticity after femtosecond laser-assisted in situ keratomileusis (FS-LASIK) procedure plays an important role in improving surgical safety and quality, since some latent complications may occur ascribing to changes in postoperative corneal biomechanics. Nevertheless, it is suggested that current research has been severely constrained due to the lack of an accurate quantification method to obtain postoperative corneal elasticity distribution. In this paper, an acoustic radiation force optical coherence elastography system combined with the improved phase velocity algorithm was utilized to realize elasticity distribution images of the in vivo rabbit cornea after FS-LASIK under various intraocular pressure levels. As a result, elasticity variations within and between the regions of interest could be identified precisely. This is the first time that elasticity imaging of in vivo cornea after FS-LASIK surgery was demonstrated, and the results suggested that this technology may hold promise in further exploring corneal biomechanical properties after refractive surgery.


Assuntos
Técnicas de Imagem por Elasticidade , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Coelhos , Animais , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Miopia/cirurgia , Lasers de Excimer , Córnea/diagnóstico por imagem , Córnea/cirurgia , Elasticidade
2.
Transl Vis Sci Technol ; 11(6): 4, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35666497

RESUMO

Purpose: Quantification of biomechanical properties of keratoconus (KC) corneas has great significance for early diagnosis and treatment of KC, but the corresponding clinical measurement remains challenging. Here, we developed an acoustic radiation force (ARF) optical coherence elastography technique and explored its potential for evaluating biomechanical properties of KC corneas. Methods: An ARF system was used to induce the tissue deformation, which was detected by an optical coherence tomography system, and thus the localized point-by-point Young's modulus measurements were achieved. Then, two healthy rabbit eyes were imaged to test the system, after which the human keratoconus cornea was evaluated by using the same method. Three regions were selected for biomechanics analysis: the conical region, the transitional region, and the peripheral region. Results: Young's moduli of transitional region ranged from 53.3 to 58.5 kPa. The corresponding values for the peripheral region were determined to be 58.6 kPa and 63.2 kPa, respectively. Young's moduli of the conical region were gradually increased by 18.3% from the center to the periphery, resulting in the minimum and maximum values of 44.9 kPa and 53.1 kPa, respectively. Furthermore, Young's moduli of the anterior and posterior of the center were determined to be 44.9 kPa and 50.7 kPa, respectively. Conclusions: Differences in biomechanical properties between the three regions and slight variations within the conical region were clearly distinguished. Biomechanical weakening of the keratoconus cornea was mainly localized in the conical region, especially in the vertex position. Translational Relevance: The system may provide a promising clinical tool for the noninvasive evaluation of local corneal biomechanics and thus may have potential applications in early keratoconus detection with further optimization.


Assuntos
Técnicas de Imagem por Elasticidade , Ceratocone , Acústica , Animais , Córnea/diagnóstico por imagem , Módulo de Elasticidade , Técnicas de Imagem por Elasticidade/métodos , Humanos , Ceratocone/diagnóstico por imagem , Coelhos
3.
J Virol Methods ; 220: 13-7, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25845624

RESUMO

A rapid immunochromatographic strip (ICS) test for specific detection of lily symptomless virus (LSV) was developed. The test is based on a double-antibody sandwich format and employs two distinct anti-LSV polyclonal antibodies (IgG1 and IgG2). The first antibody, IgG1 was used as the detection antibody conjugated to colloidal gold and the second antibody, IgG2 was used to as the capture antibody at the test line. The performance of the ICS test was evaluated and the results obtained were compared with a quadruplex RT-PCR assay. When serial dilutions of purified LSV were tested, the LSV detection limit of the ICS test was 6.0 × 10(-8)mg/mL, which was the same as the quadruplex RT-PCR assay. Relative to quadruplex RT-PCR, the specificity and sensitivity of the ICS were 98.6% and 100%, respectively for field leaf samples. There was significant agreement between the results of the ICS and quadruplex RT-PCR tests (κ = 0.983). Compared with conventional lily virus detection methods, our ICS test has many advantages: simple, fast, low cost, high sensitivity and specificity, and has applications in the laboratory and in the field to detect and control LSV.


Assuntos
Carlavirus/isolamento & purificação , Cromatografia de Afinidade/métodos , Lilium/virologia , Doenças das Plantas/virologia , Anticorpos Antivirais/imunologia , Carlavirus/imunologia , Cromatografia de Afinidade/economia , Custos e Análise de Custo , Sensibilidade e Especificidade , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA